ClearOne Converge Pro Serial User Manual
Page 29
![background image](/manuals/598131/29/background.png)
256
FLOW – Flow Control
This command selects/reports the flow control of the serial port on the unit. Hardware flow control is implemented
using DTR and DSR.
Command Form
: DEVICE FLOW [Value]
Argument Type
Size
Values
Units
Value
Unsigned Integer
4
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
FMP – First Mic Priority Mode
This command selects/reports first Mic priority mode.
Command Form
: DEVICE FMP
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
4 (G)
-
Value
Unsigned Integer
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
GAIN – Gain Adjustment
This command changes or reports back the gain for a channel.
Command Form
: DEVICE GAIN
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
1, 2, 3, 5, 7, 12, 16, 17, 25, 26 (I, J, O, M, P, L, F, T, R, K, Z,
D, U, V)
-
Value
Signed
Float
2
-99.90 – 99.90 **
(Null to query in text)
dB
Absol / Rel
0
A = Absolute
R = Relative
Null = Relative
-
NOTE: Values indicate valid range for entry values only. Actual internal range of the gain stage
is from –65 to 20. Absolute values will be limited to the internal gain range.
GATE – Gate Status
This command reports the gate status of Mics. This command is read only.
Command Form
: DEVICE GATE [Value]
Argument
Type
Size
Values
Units
Value
Hexadecimal
4
Bits 0 – 7 represent gate status on Mics 1 – 8
(Null sent in text, Value returned)
-
GHOLD – Gate Hold Time Adjust
This command selects/reports the setting of hold time.
Command Form
: DEVICE GHOLD
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
3 (M)
-
Value
Unsigned Float
2
0.10 – 8.00
(Null to query in text)