beautypg.com

ClearOne Converge Pro Serial User Manual

Page 29

background image

256

FLOW – Flow Control

This command selects/reports the flow control of the serial port on the unit. Hardware flow control is implemented
using DTR and DSR.

Command Form

: DEVICE FLOW [Value]

Argument Type

Size

Values

Units

Value

Unsigned Integer

4

0 = Off
1 = On
2 = Toggle
(Null to query in text)

-

FMP – First Mic Priority Mode

This command selects/reports first Mic priority mode.

Command Form

: DEVICE FMP [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

4 (G)

-

Value

Unsigned Integer

2

0 = Off
1 = On
2 = Toggle
(Null to query in text)

-

GAIN – Gain Adjustment

This command changes or reports back the gain for a channel.

Command Form

: DEVICE GAIN [Value] [Absol/Rel]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

1, 2, 3, 5, 7, 12, 16, 17, 25, 26 (I, J, O, M, P, L, F, T, R, K, Z,
D, U, V)

-

Value

Signed
Float

2

-99.90 – 99.90 **
(Null to query in text)

dB

Absol / Rel

0

A = Absolute
R = Relative
Null = Relative

-

NOTE: Values indicate valid range for entry values only. Actual internal range of the gain stage

is from –65 to 20. Absolute values will be limited to the internal gain range.

GATE – Gate Status

This command reports the gate status of Mics. This command is read only.

Command Form

: DEVICE GATE [Value]

Argument

Type

Size

Values

Units

Value

Hexadecimal

4

Bits 0 – 7 represent gate status on Mics 1 – 8
(Null sent in text, Value returned)

-

GHOLD – Gate Hold Time Adjust

This command selects/reports the setting of hold time.

Command Form

: DEVICE GHOLD [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

3 (M)

-

Value

Unsigned Float

2

0.10 – 8.00
(Null to query in text)

S