beautypg.com

ClearOne Converge Pro Serial User Manual

Page 60

background image

287

XAMBLVL – Ambient Level Adjust

This command selects/reports the ambient level. This command can be used to replace the AMBLVL command
for the M group.

Command Form

: DEVICE XAMBLVL [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

3, 29 (M, V)

-

Value

Signed Float

2

-80.00 – 0.00
(Null to query in text)

dB

XAARINGS – Number of Rings to Auto Answer On

This command selects/reports the setting of the number of rings to auto answer. This command can be used to
replace the AARINGS command for the R group.

Command Form

: DEVICE XAARINGS [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

17, 26 (R, Z)

-

Value

Unsigned Short

2

2-4
(Null to query in text)

-

XACONN – Audible Connect / Disconnect Indication

This command selects/reports the status of the audible connect / disconnect indication. This command can be
used to replace the ACONN command for the R group.

Command Form

: DEVICE XACONN [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

17, 26 (R, Z)

-

Value

Unsigned Short

2

0 = Off
1 = On
2 = Toggle
(Null to query in text)

-

XACONNLVL – Audible Connect / Disconnect Level

This command selects/reports the audible connect / disconnect indicator’s level. This command can be used to
replace the ACONNLVL command for the R group.

Command Form

: DEVICE XACONNLVL [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

17, 26 (R, Z)

-

Value

Signed Short

2

-12.00 – 12.00
(Null to query in text)

dB