ClearOne Converge Pro Serial User Manual
Page 64

291
XDTONELVL – Dial Tone Level
This command selects/reports the audible dial tone’s level. This command can be used to replace the DTONELVL
command for the R group. You can’t change level during a call.
Command Form
: DEVICE XDTONELVL
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
17, 26 (R, Z)
-
Value
Signed Short
2
-12.00 – 12.00
(Null to query in text)
dB
XGHOLD – Gate Hold Time Adjust
This command selects/reports the setting of hold time. This command can be used to replace the GHOLD
command for the M group.
Command Form
: DEVICE XGHOLD
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
3, 29 (M, V)
-
Value
Unsigned Short
2
0.10 – 8.00
(Null to query in text)
S
XGMODE – Gating Mode
This command selects/reports the setting of gating mode. This command can be used to replace the GMODE
command for the M group.
Command Form
: DEVICE XGHOLD
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
3, 29 (M, V)
-
Value
Unsigned Short
2
0.10 – 8.00
(Null to query in text)
-
XGOVER – Gating Override
This command selects/reports the setting of gating override. This command can be used to replace the GOVER
command for the M group.
Command Form
: DEVICE XGOVER
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
3, 29 (M, V)
-
Value
Unsigned Short
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
XGRATIO – Gate Ratio Adjust
This command selects/reports the setting of the gate ratio. This command can be used to replace the GRATIO
command for the M group.
Command Form
: DEVICE XGRATIO
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
3, 29 (M, V)
-
Value
Unsigned Short
2
0 – 50
(Null to query in text)