beautypg.com

ClearOne Converge Pro Serial User Manual

Page 25

background image

252

FE – Feedback Elimination Enable

This command enables or disables feedback elimination on the power amplifier channel.

Command Form

: DEVICE FE [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

-

Group

Group

1

23 (J)

-

Value

Unsigned Short

2

0 = On
1 = Off
2 = Toggle
(Null to query in text)

-

FEB – Feedback Elimination Bandwidth

This command sets the filter bandwidth of the notch filter. Options are a Q = 5 or Q = 10

Command Form

: DEVICE FEB [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

-

Group

Group

1

23 (J)

-

Value

Unsigned Short

2

0 = 5
1 = 10
Default 0 (5)
(Null to query in text)

-

FEDR – Feedback Elimination Dynamic Node Reset

This command will reset only the dynamic filters on the feedback eliminator. There is no query associated with this
command.

Command Form

: DEVICE FEDR

Argument Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

-

Group

Group

1

23 (J)

-

Reserved

Zero

2

Value:0-16
(Null to query in text)

Nodes

FEF – Feedback Elimination Fixed Filter

This command sets the number of fixed filter to use in the feedback eliminator. The fixed filters number will be
used during the initialization phase when gain is increased until feedback occurs. A fixed filter will be set at the
feedback point during the initialization.

Command Form

: DEVICE FEF [VALUE]

Argument Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

-

Group

Group

1

23 (J)

-

Reserved

Unsigned Short

2

Zero

-

FEG – Feedback Elimination Auto Gain Max

This command sets the target gain for auto setup in feedback cancellation.

Command Form

: DEVICE FEG [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See GroupAndChannels

-

Group

Group

1

23 (J)

-

Reserved

Unsigned Short

2

0 - 8
(Null to query in text)

dB