248
DEVICESUBTYPE – Sets the Subtype of a Connected Device
This command enables/disables or reports the current type of device connected to an input or output.
Command Form
: DEVICE DEVICESUBTYPE
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
1, 2, 3, 7 (I, O, M, L)
-
Value
Unsigned Integer
2
(NULL to query in text)
-
DEVICETYPE – Sets the Type of a Connected Device
This command enables / disables or reports the current type of device connected to an input or output.
Command Form
: DEVICE DEVICETYPE
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
1, 2, 3, 7 (I, O, M, L)
-
Value
Unsigned Integer
2
(NULL to query in text)
-
DFLTM – Default Meter
This command selects/reports the setting of the default meter on the front panel.
Command Form
: DEVICE DFLTM [Channel Group Position]
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
(Null to query in text)
-
Group
Group
1
1, 2, 3, 7, 16, 17 (I, O, M, L, T, R)
-
Position
Meter Type
2
1 – 4, as applicable for group
See Meter Type Definitions
-
DIAG – Diagnostic Commands
This command is used to return status and diagnostic information. It is intended to be used as a text command
only. This is a query only command.
Command Form
: DEVICE DIAG
Argument
Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
23 (J)
-
Value
Unsigned
Short
2
0 = List of current commands
(J) Power Amp
1 = Fan/Temp
2 = Noise Gate
3 = Feedback Nodes
-
Information
String
80
Diagnostic String
(ALWAYS NULL IN TEXT)
-
DIAL – DTMF Dialing
This command dials a DTMF sequence or reports back the last sequence dialed.
Command Form
: DEVICE DIAL
Argument
Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
17 (R)
-
Reserved
2
0
-
Number
String
40
1 – 40 Chars of ‘0’ – ‘9’, ‘*’, ‘#’, ‘,’
(Null to query last number dialed in text)
-