LVLREPORTEN – Level Report Enable
Enables level reporting for the unit.
Command Form
: DEVICE LVLREPORTEN [Value]
Argument Type
Size
Values
Units
Value
Unsigned Integer
4
0 = Turn off reporting but leave current list
1 = Turn on reporting
2 = Turn off reporting and clear the list
(Null to query in text)
-
MACRO – Macro Execution/Reporting
This command executes a specified macro or reports the last macro executed.
Command Form
: DEVICE MACRO [Value]
Argument Type
Size
Values
Units
Value
Channel
4
See 14 (C) in Groups and Channels
(Null to query last macro ran in text)
-
NOTE: The response will indicate successful execution of the macro, but it does not guarantee
that each command in the macro was executed.
MANUFACTURER – Manufacturer Identification Label
This command selects/reports the model identification label of the specified channel.
Command Form
: DEVICE MANUFACTURER
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
1, 2, 3, 7
(I, O, M, L, D)
-
Reserved
Unsigned
Integer
2
0
-
Label
String
16
1-16 characters
CLEAR = clear the label
(Null to query in text)
dB
MAX – Maximum Gain Setting
This command changes or reports back the maximum gain setting for an input, output or assignable processing
block.
Command Form
: DEVICE MAX
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
1, 2, 3, 5, 7, 12, 16, 17, 25, 26 (I, O, M, P, L, F, T, R, K,
Z, D, U, V)
-
Value
Signed Float
2
-65.00 – 20.00
(Null to query in text)
dB