REFSET – Reference Channel Set Up
This command selects/reports the output the reference channel tracks.
Command Form
: DEVICE REFSET
Argument
Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
20 (B)
-
Value
Reference Output 2
0 = none
See 2 (O) in Groups and Channels
(Null to query in text)
-
RESET – Reset
Resets the unit. There is no query for this command.
Command Form
: DEVICE RESET
No Arguments
RING – Ring Indication
This command indicates a ringing line. This command is reportable only. It cannot be queried or set.
Command Form
: DEVICE RING
Argument
Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
17 (R)
-
Value
Unsigned
Integer
2
0 = Ring Cycle Ended
1 = Ring Cycle Started
-
RINGEREN – Audible Ring Enable
This command sends/reports the use of an audible ring.
Command Form
: DEVICE RINGEREN
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
17 (R)
-
Value
Unsigned Integer
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
RINGERLVL – Audible Ring Level
This command selects/reports the audible ring’s level.
Command Form
: DEVICE RINGERLVL
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
17 (R)
-
Value
Signed Float
2
-12.00 – 12.00 (dB)
(Null to query in text)
-
RINGERSEL – Audible Ring Melody Selection
This command sends/reports the audible ring melody.
Command Form
: DEVICE RINGERSEL
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
17 (R)
-
Value
Unsigned Integer
2
1 – 3
(Null to query in text)
-