beautypg.com

ClearOne Converge Pro Serial User Manual

Page 56

background image

283

SPEEDDIAL – Speed Dial a Number

This command dials a speed dial number.

Command Form

: DEVICE SPEEDDIAL [Value]

Argument Type

Size

Values

Units

Channel

Channel

1

See Groups and Channels

-

Group

Group

1

17 (R)

-

Value

Unsigned Integer

2

1 – 20
(Null to query in text)

-

STRING – String Execution

This command sends the specified string out the serial port.

Command Form

: DEVICE STRING [ID]

Argument Type

Size

Values

Units

ID

Unsigned Integer

4

0 – 7
(Null to query last string in text)

-

SYSCHECKS – System Checks

Initiates the system checks. There is no query for this command.

The System Check integer bits determine which tests are run. Each bit set generates a separate SYSRESULT
response.

COMMAND FORM

: DEVICE SYSCHECKS

Argument Type

Size Values

System
Check

Hexadecimal
Integer

4

15 14 13 12 11 10 09 08 07 06 05 04 03 02 01 00

Network

Telephone

Mic 1

Mic 2

Mic 3

Mic 4

Mic 5

Mic 6

Mic 7

Mic 8

All other bits reserved

Packet Loss Statistics

SIP Proxy Registration Status

Power Amp Fault Check

Power Amp Temp Check