PALEN – PA Limiter Enable
This command changes enables the Limiter on a power amplifier channel.
Command Form
: DEVICE PALEN
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
23 (J)
-
Value
Unsigned Short
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-
PALT – PA Limiter Threshold
This command sets the Limiter threshold on a power amplifier channel.
Command Form
: DEVICE PALT
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
23 (J)
-
Value
Signed Float
2
-65.00 to +20.00
(Null to query in text)
dB
PANGAT – PA Noise Gate Activation Timer
This command sets the Noise Gate activation timer. The noise gate will be activated if the timer conditions are
met along with Gate thresholds.
Command Form
: DEVICE PANGAT
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
23 (J)
-
Value
Unsigned Short
2
1 -16
(Null to query in text)
Minutes
PANGEN – PA Noise Gate Enabled
This command enables noise gating on a PA Channel.
Command Form
: DEVICE PANGEN
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
23 (J)
-
Value
Unsigned Short
2
0 = No Filter
1 = High Pass
2 = Low Pass
3 = Hi and Low Pass
(Null to query in text)
-
PANGF – PA Noise Gate Filter
This command sets either a High Pass or Low Pass filter to be used in the activation of the noise gate. This will
affect the threshold conditions for activation of the gate. A low pass will remove noise floor contributions to gate
threshold above 500 HZ. A high pass will remove noise floor contribution to gate threshold above below 2K.
Command Form
: DEVICE PANGF
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
23 (J)
-
Value
Unsigned Short
2
0 = Off
1 = On
2 = Toggle