ClearOne Converge Pro Serial User Manual
Page 13
240
AGCSET – Automatic Gain Control Adjust
This command selects/reports the settings of the Automatic Gain Control.
Command Form
: DEVICE AGCSET
Argument
Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
1, 3, 7 (I, M, L)
-
Threshold
Signed Integer
1
-50 – 0
(Null to query in text)
dB
Target
Signed Integer
1
-30 – 20
dB
Response
Time
Unsigned Float
2
0.10 – 10.00
S
Gain
Unsigned Float
2
0.00 – 18.00
dB
AMBLVL – Ambient Level Adjust
This command selects/reports the ambient level.
Command Form
: DEVICE AMBLVL
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
3 (M)
-
Value
Signed Float
2
-80.00 – 0.00
(Null to query in text)
dB
AMXDUET – Use AMX Duet Discovery
This command sets and reports the status of AMX Duet Discovery.
Command Form
: DEVICE AMXDUET [Value]
Argument Type
Size
Values
Units
Value
Unsigned Integer
4
0 = Off
1 = On
2 = toggle
(Null to query in text)
-
AUDIOMASTER – Expansion Bus Audio Master Mode
This command reports the mode of the unit for control of the expansion bus audio.
Command Form
: DEVICE AUDIOMASTER [Value]
Argument Type
Size
Values
Units
Value
Unsigned Integer
4
1 = Master
2 = Slave
(Null to query in text)
-
AV – Adaptive Volume
This command enables/disables adaptive volume tracking on a power amplifier channel.
Command Form
: DEVICE AV
Argument Type
Size
Values
Units
Channel
Channel
1
See Groups and Channels
-
Group
Group
1
23 (J)
-
Value
Signed Float
2
0 = Off
1 = On
2 = Toggle
(Null to query in text)
-