beautypg.com

6 volts/hertz curve parameters (group 5), P-47 preset speed 7 model, P-48 preset speed 8 model – Rockwell Automation SP200  AC Drive, 1 2 Channel Analog, Preset Speed User Manual

Page 39: P-50 base voltage model

background image

Editing Drive Parameters

7-17

7.1.6 Volts/Hertz Curve Parameters (Group 5)

Following is a volts/hertz curve diagram and the volts/hertz parameter descriptions.

P-47 Preset Speed 7

Model

A

B

C

Use this parameter to define the
commanded drive frequency when it
is selected by the control inputs and
the drive is operating in the preset
mode.

Parameter Range:

0 to 240.0 (x.x Hz)

X

Default Setting:

50.0

X

Running Access:

RW

P-48 Preset Speed 8

Model

A

B

C

Use this parameter to define the
commanded drive frequency when it
is selected by the control inputs and
the drive is operating in the preset
mode.

Parameter Range:

0 to 240.0 (x.x Hz)

X

Default Setting:

60.0

X

Running Access:

RW

Breakpoint Frequency

(P53)

Base Frequency

(P-51)

Maximum Speed

P-01)

Base Voltage

(P-50)

Breakpoint

Voltage

(P-52)

Boost Voltage

(P-54)

0

0

Volts Per Hertz Curve

P-50 Base Voltage

Model

A

B

C

Use this parameter to set the motor
rated nameplate voltage.

Parameter Range:

0 to rated drive voltage (V)

X

X

X

Default Setting:

230 or 460

X

X

X

Running Access:

RW