Using the Local Keypad

6-1

C

HAPTER

6

Using the Local Keypad

The optional keypad can be used to change parameter values, display operating
conditions, and command drive operation. Figure 6.1 shows the SP200 drive keypad
and identifies the keypad keys.

Figure 6.1 – Keypad Functions

1

In display mode, the UP ARROW key increments the local
speed reference.
In program mode, this key increments the parameter number
or parameter value.

2

The PROGRAM key toggles between display and program
modes. The PROGRAM LED (5) turns on when the drive is in
program mode.

3

In display mode, the ENTER key scrolls through the display
parameters.
In program mode, this key toggles between the parameter
number and parameter value.

4

The RUN LED turns on when the drive is running in either the
forward or reverse direction. The RUN LED flashes while the
drive is changing direction.

5

The PROGRAM LED turns on when the drive is in program
mode.

6

In display mode, the DOWN ARROW key decrements the
local speed reference.
In program mode, this key decrements the parameter
number or parameter value.

7

The STOP key issues stop and fault reset commands to the
drive.

8

The START key issues start commands to the drive when
P-10 = 1.

9

The display shows either a parameter number or a parameter
value.

The parameter numbers are preceded by either a “P-” or a
“d-”.