2-16
GV3000/SE AC Drive Software Reference, Version 6.06
Step 6.5 Press the ▲
key to increase the value.
Important: If you are going to change the value for this parameter, see the
description in chapter 4.
The adjustment options are:
0 = Speed loop output (default setting)
1 = Terminal strip analog input
2 = Option port (network torque reference
register)
3 = Selected speed reference
VALUE ENTERED:
Step 6.6 Press the ENTER key to save the displayed value.
After pressing ENTER, the same parameter
number is displayed. You can now go to the
next parameter.
Step 6.7 Press the ▲
key to display U.001, Encoder PPR.
This parameter selects the number of pulses
per revolution (PPR) of the encoder or
selects sensorless vector control (SVC) if an
encoder is not used.
For flux vector control (FVC), when the
self-tuning procedure (step 8) is performed,
the value of this parameter is automatically
set; however, if the encoder PPR is known, it
should be entered now.
X
)RUZDUG
5HYHUVH
$872
0$1
(17(5
581
-2*
PROGRAM
67$57
6723
5(6(7
63(('
92/76
$036
+]
.Z
72548(
3DVVZRUG
5811,1*
5(027(
-2*
$872
)25:$5'
5(9(56(
352*5$0
5(/,$1&(
(/(&75,&
!
ATTENTION: The setting of parameters U.001 (Encoder PPR), U.002
(Motor Poles), U.003 (Motor Nameplate Base Frequency), U.005 (Motor
Nameplate RPM), and U.017 (Motor Top Speed) determines the motor
maximum speed. These parameters must be set by a qualified person
who understands the significance of setting them accurately. Failure to
observe this precaution could result in bodily injury.