Power Module-Dependent Parameter Default Values
C-3
Second Menu General Parameters (USA Defaults)
Second Menu Volts/Hertz Parameters (USA Defaults)
Second Menu Vector Parameters (USA Defaults)
Parameter
No.
Parameter
Name
Power Module
125R4160
200V4160
200V4160DS
250V4160
250V4160DS
300V4160
300V4160DS
350V4160
350V4160DS
400V4160
400V4160DS
P.047
Carrier Freq.
(kHz)
2
2
2
2
2
2
Parameter
No.
Parameter
Name
Power Module
125R4160
200V4160
200V4160DS
250V4160
250V4160DS
300V4160
300V4160DS
350V4160
350V4160DS
400V4160
400V4160DS
H.002
Motor Namepl.
Amps
163.0
240.0
302.0
361.0
414.0
477.0
Parameter
No.
Parameter
Name
Power Module
125R4160
200V4160
200V4160DS
250V4160
250V4160DS
300V4160
300V4160DS
350V4160
350V4160DS
400V4160
400V4160DS
U.004
Motor Namepl.
Amps
152.0
240.0
302.0
361.0
414.0
477.0
U.005
Motor Namepl.
RPM
1785
1785
1785
1785
1785
1785
U.006
Magnetizing
Current
35.0
35.0
35.0
35.0
35.0
35.0
U.012
Speed Reg.
Prop. Gain
20.00
10.00
10.00
10.00
10.00
10.00
U.013
Speed Reg. Int.
Gain
5.00
5.00
5.00
5.00
5.00
5.00
U.014
Torque Reg.
Prop. Gain
0.20
0.20
0.20
0.20
0.20
0.20
U.015
Torque Reg.
Integral Gain
100.0
100.0
100.0
100.0
100.0
100.0
U.016
Field Weaken
Start RPM
1785
1785
1785
1785
1785
1785
U.017
Motor Top
Speed
1785
1785
1785
1785
1785
1785
U.019
Flux Current
Reg. Prop. Gain
0.15
0.15
0.15
0.15
0.15
0.15
U.20
Flux Current
Reg. Int. Gain
50.0
50.0
50.0
50.0
50.0
50.0
U.21
Rotor Time
Constant
350
350
350
350
350
350
U.022
Motor Namepl.
HP
150.0
200.0
250.0
300.0
350.0
400.0
U.032
SVC Flux Curr.
Reg. Gain
450
400
350
300
250
250