beautypg.com

Rockwell Automation AutoMax Enhanced Ladder Language Reference Manual User Manual

Page 83

background image

4Ć23

4.6.1

Input Parameters for the Limit Instruction

This table lists the inputs for the LIMIT instruction and the variable type and data

type/range that each input supports.

Parameter Description

Variable Type

Data Type/Range

EN

When this input is true, the instruction executes. When

this input is false, the instruction is not executed and

ENO is false.

Connect a Boolean input or output.

Mx

Enter the upper limit for In.

D simple
D constant

D integer
D double integer

In

Enter the variable that you want to limit.

D element of an array

g

D timer (name.TPreset

and name.Elapsed)

D counter

Mn

Enter the lower limit for In.

D counter

(name.CPreset and