beautypg.com

Rockwell Automation AutoMax Enhanced Ladder Language Reference Manual User Manual

Page 149

background image

7Ć3

7.1.1

Input Parameters for the Convert Integer Data to BCD Instruction

This table lists the inputs for the TO_BCD instruction and the variable and type and data

type/range that each input supports.

Parameter

Description

Variable Type

Data Type/Range

EN

While this input is true, the instruction executes. When this

input is false, the instruction is not executed and ENO is

false.

Connect a Boolean input or output.

In

Enter the variable that you want converted to binary

coded data.

D simple
D constant
D element of an array

D integer

(0 to 9999)

D double integer

(0 to 99999999)

D timer

(name.TPreset

and

name.Elapsed)

D counter

(name.CPreset

and

name.Current)