4Ć7

4.2.1

Input Parameters for the Greater Than Or Equal To Instruction

This table lists the inputs for the GE instruction and the variable type and data

type/range that each input supports.

Parameter

Description

Variable Type

Data Type/Range

EN

When this input is true, the instruction executes. When

this input is false, the instruction is not executed and

ENO is false.

Connect a Boolean input or output.

In1
In2
In3

Enter the parameters you want to compare in these inĆ

puts. You must specify something for at least In1 and

In2. In3 is optional.

D simple
D constant
D element of an array

D integer
D double integer
D timer

(name.TPreset and

name.Elapsed)

D counter

(name.CPreset and

name. Current)