Be aware of the following conditions:

CAUTION: Avoid jumping backwards an excessive number of times since this

can cause a STOP ALL error code 14, which is the Processor Overlap Limit

Exceeded error. Failure to observe this precaution could result in damage to, or

destruction of, the equipment.

CAUTION: Avoid skipping timer instructions using a JMP instruction. The

timer's Boolean output will not get set if the timer does not execute. Failure to

observe this precaution could result in damage to, or destruction of, the

equipment.

11.1

Set Event (SET)

Use the Set Event instruction to synchronize a ladder program with another program of

any type within the same rack. When EN transitions from off to on (falseĆtoĆtrue), it sets

the name of a software event (Event Name).