Cables: panelview plus to communication adapters – Rockwell Automation 2711P PanelView Plus Terminal User Manual User Manual
Page 168
![background image](/manuals/580687/168/background.png)
168
Publication 2711P-UM001J-EN-P - November 2009
Chapter 7 Terminal Connections
PanelView Plus and PanelView Plus CE Terminals to Logix Controllers
PanelView Plus Terminals to Communication Adapters
Cables: PanelView Plus and PanelView Plus CE to Logix Controllers
Protocol
PanelView Plus Comm Port
ControlLogix
CH0 (9-pin RS-232)
(DF1)
CompactLogix
CH0 (9-pin RS-232)
(DF1 or DH-485)
DF1
(any)
RS-232 (DF1) Port (9-pin)
PanelView Plus 400 to 1500
2711P-RN22C
2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)
2706-NC13 (3 m/10 ft)
DH-485
(any)
RS-232 (DH-485) Port (9-pin)
PanelView Plus 400 to 1500
2711P-RN22C
N/A
2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)
2706-NC13 (3 m/10 ft)
DH-485 Port
PanelView Plus 400 and 600
2711P-RN3
(2)
,
PanelView Plus 700 to 1500
2711P-RN6, -RN6K
(2)
For CE compliance, use the 1761-NET-AIC or 1747-AIC module for cable lengths longer than 30 m (98 ft).
N/A
Use AIC+ Module
(1761-NET-AIC)
Connect to Port 3
ControlNet
ControlNet Port
PanelView Plus 400 and 600
2711P-RN15C
PanelView Plus 700 to 1500
2711P-RN15S, -RN15SK
Use 1756-CNB Module with ControlNet Cable
1769-L35CR, -L32C, -1768-CNB, or 1768-CNBR
with ControlNet Cable
DeviceNet
(1)
(1)
DeviceNet and Remote I/O communication modules are no longer available. Cable information is provided for reference only.
DeviceNet Port
PanelView Plus 400 and 600
2711P-RN10C
PanelView Plus 700 to 1500
2711P-RN10H
Use 1756-DNB Module
with DeviceNet Cable
Use 1769-SDN Module
with DeviceNet Cable
EtherNet/IP
EtherNet/IP Port
PanelView Plus 400 to 1500
All except 2711P-xxx5xx
Use 1756-EN2T or 1756-ENBT Module with
1585J-M Type Cable or
2711P- CBL-EX04 (4 m/14 ft)
(3)
(3)
For a direct connection between the terminal and controller, use the 2711P-CBL-EX04 crossover cable.
To 1769-L35E, L23E, L32E,
or 1768-ENBT Module with 1585J-M Type Cable
or 2711P- CBL-EX04 (4 m/14 ft)
Remote I/O
Remote I/O Port
PanelView Plus 400 to 1500
2711P-RN1, 2711P-RN6
Use 1756-DHRIO Module
with
Shielded Twinaxial Cable (1770-CD)
N/A
DH+
DH+ Port
PanelView Plus 400 and 600
2711P-RN8
PanelView Plus 700 to 1500
2711P-RN6, -RN6K
Use 1756-DHRIO Module
with
Shielded Twinaxial Cable (1770-CD)
N/A
Cables: PanelView Plus to Communication Adapters
Protocol
PanelView Plus Comm Port
1747-AIC
1761-NET-AIC
Port 1 (9-pin)
Port 2
8-pin Mini DIN()
Port 3
(DH-485)
1761-NETDNI
or 1771-NET-ENI
DF1 (any)
RS-232 Port (9-pin)
PanelView Plus 400 to 1500
2711P-RN22C (for 400 and 600)
N/A
2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)
2706-NC13 (3 m/10 ft)
2711-NC21 (5 m/16 ft)
2711-NC22 (15 m/49 ft)
N/A
1761-CBL-AP00 (5 m)
1761-CBL-PM02 (2 m)
2711-CBL-PM05 (5 m)
2711-CBL-PM10 (10 m)
DH-485
(any)
RS-232 Port (9-pin)
PanelView Plus 400 to 1500
2711P-RN22C (for 400 and 600)
N/A
2711-NC13 (5 m/16 ft)
2711-NC14 (10 m/32 ft)
2706-NC13 (3 m/10 ft)
2711-NC21 (5 m/16 ft)
2711-NC22 (15 m/49 ft)
N/A
DH-485 Port
PanelView Plus 400 and 600
2711P-RN3
(1)
1747-C10 (2 m/6ft)
1747-C11 (0.3 m/1 ft)
1747-C20 (6 m/20 ft)
N/A
1761-CBL-AS03
(3 m/10 ft)
1761-CBL-AS09
(9 m/30 ft)
to single AIC+
N/A
DH-485 Port
PanelView Plus 700 to 1500
2711P-RN6, -RN6K
Direct Connection to
Single AIC with
Belden 9842 Cable
(2)
N/A
Direct Connection to
Single AIC+ with
Belden 9842 Cable
N/A
(1)
For CE compliance, use the 1761-NET-AIC or 1747-AIC module for cable lengths longer than 30 m (98 ft).
(2)
Use serial port on the PanelView Plus terminal with an AIC+ module for a DH-485 network solution.