beautypg.com

Attach the touch screen connector, Replace the sealing gasket, Replace the backlight – Rockwell Automation 2711P PanelView Plus Terminal User Manual User Manual

Page 158: Disconnect power from the terminal, Remove the display module bezel

background image

158

Publication 2711P-UM001J-EN-P - November 2009

Chapter 6 Install and Replace Components

4. Attach the touch screen connector.

5. Replace the sealing gasket.

6. Attach the screws that secure the display module to the bezel

and tighten to a torque of 1.35…1.58 Nm (12…14 lb•in).

7. On touch screen terminals, reattach the small metal plate to the

back of the display module using two screws and torque to
0.58 Nm (5…7 lb•in).

Replace the Backlight

This section shows how to replace the backlight for the 700, 1000,
1250, and 1500 terminals. The 1250 high-bright terminals do not have
a replaceable backlight.

Follow these steps to replace the backlight.

1. Disconnect power from the terminal.

2. Remove the display module bezel.

3. Remove the four screws that secure the display bracket for the

700 series C display.

Backlights for PanelView Plus 700 to 1500 Displays

Use Cat. No.

For Display

Series

# of Backlights

2711P-RL7C

700

A and B

1

2711P-RL7C2

C

1

2711P-RL10C

1000

A

1

2711P-RL10C2

B and C

1

2711P-RL12C

1250

A and B

2

2711P-RL12C2

C

1

2711P-RL15C

1500

B

2

IMPORTANT

Disposal: The backlights for these products contain mercury.
Dispose of per applicable laws.

IMPORTANT

The 700 series C display is not secured by screws and is only
retained by a bracket. Use care not to drop the display once the
bezel is removed.