Use the datalog feature, Configure datalog – Rockwell Automation 2080-LC20-20QBBR Micro820 20-point Programmable Controllers User Manual User Manual
Page 96

88
Rockwell Automation Publication 2080-UM005A-EN-E - December 2013
Chapter 9
Using microSD Cards
Use the Datalog Feature
Configure datalog
1.
In Connected Components Workbench, go to the Properties pane to
configure your datalog.
2.
Select Datalog. Click Add Dataset to add a dataset. Note that each dataset
will be stored in the same file. You can add up to 10 datasets per
configuration.
3.
Click Add Variable to add variables to the dataset. You can add up to 128
variables to each dataset.
For this quickstart sample project, add the following variables that you
have previously created to Dataset 1.
Local Variables
Variable Name
Data Type
data_bool
BOOL
data_int8
INT
data_string
STRING
This manual is related to the following products:
- 2080-LC20-20AWBR Micro820 20-point Programmable Controllers User Manual 2080-LC20-20QWBR Micro820 20-point Programmable Controllers User Manual 2080-LC20-20AWB Micro820 20-point Programmable Controllers User Manual 2080-LC20-20QBB Micro820 20-point Programmable Controllers User Manual 2080-LC20-20QWB Micro820 20-point Programmable Controllers User Manual