Appendix D Application notes for FactoryTalk Transaction Manager
N7:0,L100
(a block of 100 integers from N7:0 to N7:99) and pass
this value to the stored procedure as outlined below. This stored
procedure uses a table created with the
CREATE TABLE
testerout(run INT,my_val INT)
command.
NOTE
The stored procedures only accept positive integers from 0 to 32,767.
CREATE PROCEDURE chunk_eater(@in_binary VARBINARY(255))
AS
DECLARE
@offset INT,
@string_len INT,
@in_byte_int INT,
@loop INT,
@upper_word VARBINARY(2),
@lower_word VARBINARY(2)
BEGIN
SELECT @string_len = DATALENGTH(@in_binary)
SELECT @loop = 1
WHILE @string_len >= @loop
BEGIN
--------------------------------------------------------------
Note: This procedure only accepts positive integers. You may
modify the upper
-- word of each integer for negative integer values.
--------------------------------------------------------------
--------------------------------------------------------------
You can view the following code using upper_word and lower_word.
The values are
-- inserted into a TESTEROUT table, which records the integer value
(in my_val) and
-- the "run" or integer location. The location for sending a data
block of n7:0,L100
-- results in value of 199. To alter this inversion, subtract the
current location
-- from the string length.
--------------------------------------------------------------
SELECT @upper_word = SUBSTRING(@in_binary,(@string_len -
@loop)+0,1)
SELECT @lower_word = SUBSTRING(@in_binary,(@string_len -
@loop)+1,1)
-- lines directly above substring out the 2 bytes of the word
-- they are combined in reverse order for byte swapping.
SELECT @in_byte_int = CONVERT(int,(@lower_word+@upper_word))
INSERT INTO testerout(run,my_val) VALUES (@loop,@in_byte_int)