Migrating RSBizWare Chapter 4
Privilege
Description
Type of Author activation required
View Time-Series
Comment
(FactoryTalk Historian Classic users only) Allows the selected
user or group to view the Value, X-Axis, and Y-Axis comments
that have been associated with time-series data.
None
Add Time-Series
Comment
(FactoryTalk Historian Classic users only) Allows the selected
user or group to associate Value, X-Axis, and Y-Axis comments
with time-series data.
None
Edit/Delete
Time-Series Comment
(FactoryTalk Historian Classic users only) Allows the selected
user or group to modify and delete Value, X-Axis, and Y-Axis
comments that have been associated with time-series data.
None
Manage Performance
Parameters
Allows the selected user or group to use the FactoryTalk
Metrics Performance Parameters dialog box to specify the
parameters that will be used in the calculation of OEE for an
activity area.
FactoryTalk Metrics Author
Manage FactoryTalk
Metrics Manual Data
Collection
Allows the selected user or group to modify and delete
FactoryTalk Metrics work cell data.
FactoryTalk Metrics Author
Manage Time Pattern Allows the selected user or group to create and modify time
patterns, configure composites, and schedule exceptions.
FactoryTalk Metrics Author
TIP
If you are migrating the RSBizWare suite to two computers, perform the
following steps on the Target RSBizWare server computer.
To restore your FactoryTalk Transaction Manager
configuration:
1. Copy the backup of your FactoryTalk Transaction Manager
configuration that you created in "Step 1: Back up your
FactoryTalk Transaction Manager configuration (page 115)"
from the source computer to the computer on which you are
performing these steps.
2. On the Start screen, type any part of the name FactoryTalk
Transaction Manager, and then click its shortcut.
The FactoryTalk Transaction Manager window appears.
3. On the Configuration menu, click Restore.
The Remote rsq File Browse dialog box appears.
Step 27: Restore your
FactoryTalk Transaction
Manager configuration