Appendix D Application notes for FactoryTalk Transaction Manager
If these conditions are not met, the paste operation is
terminated.
• You cannot perform a paste when a configuration is running
or if the configuration has pending edits.
FactoryTalk Transaction Manager supports sending error messages
to the Windows Event Viewer. If you have defined error logging in
FactoryTalk Transaction Manager and no messages display when
you view error log files, make sure you are looking in the Application
event log in the Windows Event Viewer.
To trace a FactoryTalk Transaction Manager problem in the
Windows Event Viewer:
1. Go to Start > Administrative Tools > Event Viewer.
2. The Event Viewer dialog box appears.
3. Expand Windows Logs.
4. Right-click Application, and then click Filter Current Log.
The Filter Current Log dialog box appears.
5. Select check boxes next to all the event levels (Critical,
Warning, Verbose, Error, Information).
6. In the Event sources list, select RSSql.
7. (Optional) In the Task category list, select a specific category.
8. Click OK.
The application logs are filtered and display only the logs
related to FactoryTalk Transaction Manager.
FactoryTalk Transaction Manager does not support RSLinx Classic
as an application. You must run RSLinx Classic as a Windows
2012/2008/2003 service.
Windows Event Viewer tips
Running RSLinx Classic as a
service
296