Chapter 7 Administering RSBizWare servers
Value name (units)
Default
value
Description
Location in pre-RSBizWare 9.0
software
LogLocation CalcThreadFault
Metrics (On or Off)
Off
Turns the application-specific informational
and debug-level logging on or off for fault
metric calculation messages in the
Calculator thread.
The LogLocation registry value, with bit 200
set in the hexadecimal bitmask.
LogLocation CalcThreadMachine
State (On or Off)
Off
Turns the application-specific informational
and debug-level logging on or off for
machine state calculation messages in the
Calculator thread.
The LogLocation registry value, with bit 400
set in the hexadecimal bitmask.
LogLocation ServerRequests (On
or Off)
Off
Turns the application-specific informational
and debug-level logging on or off for server
request handling.
The LogLocation registry value, with bit
1000 set in the hexadecimal bitmask.
LogLocation DataProcessing
Queue (On or Off)
Off
Turns the application-specific informational
and debug-level logging on or off for data
processing queue handling.
The LogLocation registry value, with bit
4000 set in the hexadecimal bitmask.
LogLocation Memory
Management (On or Off)
Off
Turns the application-specific informational
and debug-level logging on or off for
messages in the Memory Management
thread.
This value did not exist in versions of the
software prior to RSBizWare 9.0.
StartupRSLAgeLimit (Minutes) 10
Discards the first RSL file processed if it is as
many minutes older than the current time
as specified in the value.
The RSL Check Time Duration registry value.
InitializeFromSingle Timestamp
(1 or 0)
1
1 - Initialize data collection from a single
timestamp provided by the heart beat
transactions and discard data that is older
than the initializing time.
0 - Use all data regardless of the timestamp.
The Init Values Type registry value.
ShiftRecursion Duration
(Minutes)
60
The amount of time used to recursively
search for the start of the current shift.
The Shift Recurse Gap registry value.
Summarization Overlap
(Seconds)
2
Summarization criteria changes that occur
within this amount of time will be
considered a single change and will not
generate multiple summarizations.
The Summarization Gap registry value.
DataQueueSleep Threshold (# of
Data Queue Items)
100
The number of items waiting to be
processed. If the number is exceeded, the
Calculator thread remains awake for a small
amount of time not to consume all the CPU
time. This is the number of items indicating
that the server is busy enough so that it does
The Sleep Threshold registry value.
218
Rockwell Automation Publication BZWARE-IN001M-EN-P-June 2014