Editing a Procedure

Chapter 7

7Ć15

You can also remove a procedure in this edit mode. However, before the
1775-S4B removes it the from the symbol table, you must enter the
following:

RS,[ENTER]

The 1775-S4B scanner removes the procedure name from the symbol
table.

You can generate a listing of all symbols and their memory addresses by
entering:

LS [ENTER]

The 1775-S4B scanner displays a list of all symbols. For more information
on editing messages through the 1775-S4A scanner, refer to the PLC-3
Programmable Controller Programming Manual (publication 1775-6.4.1,
formerly 1775-801).

Table 7.B

1775ĆS4A Scanner Editing Commands

Command

Keyboard Entry

Move 1 character to the right
Move 1 character to the left
Move 1 line up
Move 1 line down
Move 10 lines up
Move 10 lines down
Delete the character at the cursor
Delete the message procedure from the message area
Delete the characters from the cursor through the end of the line
Insert the next character into the message procedure

1

Exit 1775ĆS4A message editor

[

]

[

]

[

]

[

]

[RUNG

]

[RUNG

]

[DELETE]
[CTRL] D
[TRUNC]
[INSERT]
[CNCL CMD]

1

You can use this command to store the control commands listed in this table in your procedure. Otherwise, the command

executes when you enter the keystroke.