Using Commands in Report Generation

Chapter 10

10Ć5

Table 10.A

Command Section Modifiers

Section Modifier

Abbreviation

Type of Message File to Generate

Report
Comment
Terminal
Highway
Assist

/R
/C

/T

/H
/A

Report Generation Message Procedure
Rung Comment
Macro Commands
Data Highway Message Procedure
Help Message

The default modifiers are local for the scope modifier and report for the
section modifier.

You can also use the delete command within a procedure to delete a user
symbol. Refer to section 10.3.11 for detailed information.

If you delete a procedure name from the system symbol table, you remove
the procedure name and contents from PLC-3 memory.

Examples using the delete command:

If you enter:

S4B> DEL @AB

The 1775-S4B scanner deletes the local report generation system symbol
@AB.

If you enter:

S4B> DEL/G/H @DH2

The 1775-S4B scanner deletes the global highway procedure @DH2.

Definition: To duplicate a procedure.

Abbreviation: CO

Format: CO//

@
@

Description: You can use the copy command to duplicate a procedure.
The original name is the procedure that you want to copy . The copy name
is the procedure name for the copy. When the 1775-S4B scanner executes
the copy command, it does not delete the original procedure.

10.2.5
Copy