Sample Application Programs
Chapter 10
10Ć12
Important: Note that:
due to the specified acceleration and deceleration rate of move #14, the axis
will not achieve the final velocity rate of 5 in/s
because moves #16 and #17 have discrete input triggers which may be
triggered at any time during their movements profiles, the axis may not
achieve the final velocity rates of 2 in/s and 3 in/s
all motion segments and programmable I/O information could be contained
in a single motion block. Three motion blocks are used here to demonstrate
the recommended method of loading multiple motion blocks into a module.
Planning the Data Blocks for Application Program #2
For application program 2 a PLC-5/15 processor is assumed and the data blocks
are assigned as shown in Table 10.C. The files used are shown in Table 10.D.
The data table for the parameter block for application program 2 is the same as
shown in Figure 10.4, for application program 1.
Table 10.C
Data Blocks for Application Program # 2
Block
Starting Address
Status
N44:1
Parameter
N45:1
Command
N45:131
Motion
N80:1
Table 10.D
Files for Application Program #2
File
Size
(Elements)
Usage
B3
2
last block transfer toggle control
R6
3
sequencer control
N7
10
block transfer control
D9
20
sequencer data
N44
34
status block
N45
145
parameter, command blocks
N80
53
motion block