MTS SWIFT 20 Ultra Sensor User Manual
Page 56
SWIFT 20 Sensors
56
TISETZERO – Low-Profile Transducer Interface Set
Software Utilities
TISETZERO – Low-Profile Transducer Interface Set
Zero Method
This program allows some configuration settings to be changed in a SWIFT
Low-Profile Transducer Interface (TI) without modifying a settings file. This
program only changes configuration settings, it does not change any calibration
settings.
Syntax
:
tisetzero port box [zero_algo]
port is the communications
1 = COM1:
2 = COM2:
box is the Low-Profile TI communications address
1 = lowest possible address
9 = highest possible address
zero_algo is optional and specifies the zero algorithm
0 = lowest
4 = highest
Example
Option 0
Use this option to exit the program
Option 1
Use this option for fixed (non-spinning) applications. It sets the AngleMode to 1
(fixed) and the ZeroAlgorithm to 0 (fixed). You may need to set the fixed angle
manually.
Option 2
Use this option for spinning applications. It sets the AngleMode to 0 (encoder)
and the ZeroAlgorithm to 1 (spinning bridge, angle with level).
Option 3
Use this option for spinning applications. It sets the AngleMode to 0 (encoder)
and the ZeroAlgorithm to 3 (spinning bridge and angle)
Option 4
Use this option for spinning applications. It sets the AngleMode to 0 (encoder)
and the ZeroAlgorithm to 4 (2-point bridge and angle with level).
C:\bin>tisetzero 1 1
Firmware Version: 2.6.1
Current angle mode is ENCODER
Current zero algorithm is SPINNING BRIDGE AND ANGLE UNLOADED
Zero algorithms...
0) exit
1) fixed
2) spinning bridge
3) spinning bridge and angle unloaded
4) spinning 2 point
Enter choice?