beautypg.com

Specifications, Specifications 25 – MTS SWIFT 20 Ultra Sensor User Manual

Page 25

background image

Specifications

SWIFT 20 Sensors

Hardware Overview

25

Specifications

SWIFT 20 Transducer Performance

Parameter

Specification

Use

SWIFT 20 A (aluminum) for

SWIFT 20 T (titanium) for

low weight, high sensitivity

high fatigue life, durability

Maximum usable rpm

2,200

Maximum speed

240 kph (150 mph)

fits rim size (usable range)

12–15 inch

*

*

A special flange configuration is required for a 12 inch wheel. Larger diameter rims can be used, providing that overall
clearance from brake calipers and suspension components is maintained.

Maximum hub bolt circle diameter
accommodates M12 or 1/2 inch studs

4.5 inch (114.3 mm)

Input voltage required

10–17 VDC

Input power required per transducer

30 W maximum (22 W typical)

Output voltage ± full scale calibrated load

±10 V

Load impedance >1 k

Ω

; 0.01 µF (maximum) load capacitance.

SAE J328 rated load capacity

Aluminum

Titanium

4.3 kN (965 lbf)

7.0 kN (1,580 lbf)

Standard Maximum Calibrated Load Rating

The actual calibrated range may be different based on individual customer requirements. Consult the calibration range
sheet that accompanies each transducer for the correct calibration range.

Longitudinal force (Fx)

±21 kN (±4,720 lbf)

±30 kN (±6,745 lbf)

Lateral force range (Fy)

±16 kN (±3,595 lbf)

±25 kN (±5,620 lbf)

Vertical force range (Fz)

±21 kN (±4,720 lbf)

±30 kN (±6,745 lbf)

Overturning moment (Mx)

±4 kN•m (±35,405 lbf•in)

±6 kN•m (±53,105 lbf•in)

Driving/braking moment (My)

±5 kN•m (±44,255 lbf•in)

±8.5 kN•m (±75,230 lbf•in)

Steering moment (Mz)

±4 kN•m (±35,405 lbf•in)

±6 kN•m (±53,105 lbf•in)

Resolution (analog system)

Infinite

Noise level (peak-to-peak 0-500Hz)

15 N (3.4 lbf)

25 N (5.6 lbf)

Performance accuracy

Nonlinearity

1.0% full scale

Hysteresis

0.5% full scale

Modulation

§

§

Typical value on most steel rims. Aluminum rims typically have slightly higher modulation, but at a lower added weight.

≤3.0% reading

Cross talk

#

#

Each SWIFT sensor is calibrated on an MTS calibration machine. MTS provides complete documentation of calibration
values for each SWIFT unit

1.5% full scale

Maximum operating temperature

Low level amplifiers

Transducer interface

70°C (158°F)

50°C (122°F)