Dc−bus operation – Lenze EVF9333−xV User Manual
Page 468

DC−bus operation
Fuses and cable cross−sections
10.3
l
10.3−2
EDSVF9333V EN 6.2−04/2012
Inverter
DC fuse 14 × 51
(EFSGR0xx0AYHx)
DC fuse 22 × 58
(EFSGR0xx0AYIx)
Installation in
accordance with
EN 60204−1
Type
Mains
Rated current of fuse
Rated current of fuse
+U
G
, −U
G
Laying system
B2
C
[A]
[A]
[mm
2
]
[mm
2
]
EVF9321−xV
3/PE
400 V
12
12
1.5
1.5
EVF9322−xV
12
12
1.5
1.5
EVF9323−xV
12
12
1.5
1.5
EVF9324−xV
20
20
1.5
1.5
EVF9325−xV
40
40
4
4
EVF9326−xV
50
50
6
1)
4
1)
Pin−end connector required, since a maximum cable cross−section of 4 mm
2
can be connected to
the inverter.
Inverter
DC fuse NH1
(EFSGRxxx0ANVx)
DC fuse 22 × 58
(EFSGR0xx0AYIx)
Installation in
accordance with
EN 60204−1
Type
Mains
Rated current of fuse
Rated current of fuse
+U
G
, −U
G
Laying system
B2
C
[A]
[A]
[mm
2
]
[mm
2
]
EVF9327−xV
3/PE
400 V
100
100
−
25
EVF9328−xV
100
100
−
25
EVF9329−xV
200
−
−
25
EVF9330−xV
200
−
−
50
Inverter
DC fuse NH2
(EFSGRxxx0ANWx)
DC fuse 22 × 58
(EFSGR0xx0AYIx)
Installation in
accordance with
EN 60204−1
Type
Mains
Rated fuse current
Rated fuse current
+U
G
, −U
G
Laying system
F
C
[A]
[A]
[mm
2
]
[mm
2
]
EVF9331−xV
3/PE
400 V
250
−
−
95
EVF9332−xV
350
−
−
95
EVF9333−xV
350
−
95
−