Configuration – Lenze EVF9333−xV User Manual
Page 292

Configuration
Function blocks
Internal motor control with V/f characteristic control (MCTRL1)
8.2
8.2.6
l
8.2−30
EDSVF9333V EN 6.2−04/2012
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0105 QSP Tif
5.00
0.00
{0.01 s}
999.90 Quick stop deceleration time
l
The deceleration time refers to
a speed variation of C0011 ... 0
^
8.2−25
^
8.2−48
C0107 holding time
0.00
0.00
{0.01 s}
9999.90 Hold time for automatic DC
injection braking (Auto−GSB)
^
8.2−25
^
8.2−48
C0132
s
Controller
enable fly
delay
à
0
{1 ms}
9999 Minimum time for controller
inhibit with active flying restart
circuit, delays the start of the
flying restart process after
controller enable
à
depending on C0082, C0086,
C0087, C0088, C0089, C0090,
C0091, C0092
A change of one of the codes
resets C0132 to the minimum
time of the selected motor
l
The time is derived from the
double rotor time constant
^
8.2−25
^
8.2−48
C0140
s
select direct
0
Search direction during flying
restart process
l
Positive direction of rotation:
The motor rotates in CW
direction with view on the
motor shaft
l
Negative direction of rotation:
The motor rotates in CCW
direction with view on the
motor shaft
^
8.2−25
^
8.2−48
0
NSET
Only search in the direction of the
applied setpoint
1
inv. Nset
Only search against the direction
of the applied setpoint
2
pos.
Only search in positive direction of
rotation
3
neg.
Only search in negative direction
of rotation
4
Both, Nset
Search at first in the direction of
the applied setpoint and then
against the direction
5
Both, inv. Nset
Search at first against the
direction and then in the direction
of the applied setpoint
6
Both pos.
Search at first in positive then in
negative direction of rotation
7
Both neg.
Search at first in negative then in
positive direction of rotation