Configuration, Code table – Lenze EVF9333−xV User Manual
Page 350

Configuration
Code table
8.5
l
8.5−2
EDSVF9333V EN 4.0−11/2007
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0005
s
Signal CFG
Selection of the basic
configuration
1000 0
Common
Modified basic
configuration
The first two digits indicate the
predefined basic function, e. g.:
l
01xxx: Speed control
The third digit indicates additional
functions:
l
xx0xx: No additional function
l
xx1xx: Brake control
l
xx2xx: Setpoint selection via
motor potentiometer
l
xx3xx: PID controller
l
xx4xx: Mains failure control
l
xx5xx: Setpoint selection via
master frequency
l
xx6xx: Gearbox factor − analog
trimming
l
xx7xx: Gearbox factor − digital
trimming
l
xx8xx: Master frequency ramp
function generator
The fourth digit indicates the
predefined voltage source for the
control terminals:
l
xxx0x: External supply voltage
l
xxx1x: Internal supply voltage
The fifth digit indicates the
predefined device control
l
xxxx0: Terminal control
l
xxxx1: RS232, RS485 or optical
fibre
l
xxxx3: INTERBUS or
PROFIBUS−DP
l
xxxx5: System bus (CAN)
100
CFG: emty
All internal
connections are
removed
1000
Speed mode
Speed control
2000
Step mode
Step control
3000
Lead screw
Traversing control
4000
Torque mode
Torque control
5000
DF master
Digital frequency
master
6000
DF slv bus
Master frequency
slave (bar)
7000
DF slv cas
Digital frequency
slave (cascade)
8000
Dancer ctrl e
Dancer position
control with
external diameter
measurement
9000
Dancer ctrl i
Dancer position
control with
internal diameter
measurement
C0006
s
Op mode
5
Selection of the operating mode
for the motor control
1
vector ctrl
Vector control
without or with
speed feedback
In case of the first selection enter
the motor data and identify them
with C0148.
^ 6.8−8
5
V / f
V/f characteristic
control
Commissioning without
identification of the motor data is
possible
l
Advantage of identification
with C0148: Improved smooth
running at low speeds
^ 6.8−4
C0009 LECOM address
1
1
{1}
99 LECOM controller address
l
Bus device number when
operated via interface
l
10, 20 ... 90 reserved for
broadcast to device groups
with RS232, RS485, optical
fibre