Configuration, Code table – Lenze EVF9333−xV User Manual
Page 408

Configuration
Code table
8.5
l
8.5−60
EDSVF9333V EN 4.0−11/2007
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0912 OV delay time
à
−
{1 ms}
− Delay time of the pulse enable
after an OU message
à
Depending on C0082, C0086,
C0087, C0088, C0089, C0090,
C0091, C0092
A change of one of the codes
resets C0912 to the time of the
selected motor
l
The time is derived from the
double rotor time constant
^
8.2−25
^
8.2−48
^ 9.4−3
C0913
s
OV handling
0
Value of the motor current during
the flying restart process or after
an OU message
l
When C0913 = 1, the motor is
driven with reduced current to
the setpoint speed during the
flying restart process of after
an OU message.
l
The setting is only effective for
the drives EVF9326 ... EVF9333
^
8.2−25
^
8.2−48
0
inactive
Non−reduced motor current
1
active
Reduced motor current
C0940 Numerator
1
−32767
{1}
32767 Configuration of conversion factor
with numerator and denominator,
function block CONV1
See System
Manual
(extension)
C0941 Denominator
1
1
{1}
32767
OUT [%]
+ IN [%] @ C0940
C0941
C0942
s
CFG: IN
1000 FIXED0%
^ Selection list 1
Configuration of analog input
signal, function block CONV1
C0943 DIS: IN
−199.99
{0.01 %}
199.99 Function block CONV1
l
Display of the signal linked in
C0942
C0945 Numerator
1
−32767
{1}
32767 Configuration of conversion factor
with numerator and denominator,
function block CONV2
See System
Manual
(extension)
C0946 Denominator
1
1
{1}
32767
OUT [%]
+ IN [%] @ C0945
C0946
C0947
s
CFG: IN
1000 FIXED0%
^ Selection list 1
Configuration of analog input
signal, function block CONV2
C0948 DIS: IN
−199.99
{0.01 %}
199.99 Function block CONV2
l
Display of the signal linked in
C0947
C0950 Numerator
1
−32767
{1}
32767 Configuration of conversion factor
with numerator and denominator,
function block CONV3
See System
Manual
(extension)
C0951 Denominator
1
1
{1}
32767
OUT [%]
+ IN [rpm] @
100 %
15000 rpm
@ C0950
C0951
C0952
s
CFG: IN
1000 FIXED0%
^ Selection list 1
Configuration of analog input
signal, function block CONV3
C0953 DIS: IN
−199.99
{0.01 %}
199.99 Function block CONV3
l
Display of the signal linked in
C0952
C0955 Numerator
1
−32767
{1}
32767 Configuration of conversion factor
with numerator and denominator,
function block CONV4
See System
Manual
(extension)
C0956 Denominator
1
1
{1}
32767
OUT [%]
+ IN [rpm] @
100 %
15000 rpm
@ C0955
C0956
C0957
s
CFG: IN
1000 FIXED0%
^ Selection list 1
Configuration of analog input
signal, function block CONV4
C0958 DIS: IN
−199.99
{0.01 %}
199.99 Function block CONV4
l
Display of the signal linked in
C0957