Configuration, Code table – Lenze EVF9333−xV User Manual
Page 370

Configuration
Code table
8.5
l
8.5−22
EDSVF9333V EN 4.0−11/2007
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0260 MPOT1 high
100.0
0
−199.99
{0.01 %}
199.99 Upper limit, function block MPOT1
l
Condition: C0260 > C0261
See System
Manual
(extension)
C0261 MPOT1 low
−100.0 −199.99
{0.01 %}
199.99 Lower limit, function block MPOT1
l
Condition: C0261 < C0260
C0262 MPOT1 TIR
10.0
0.1
{0.1 s}
6000.0 Acceleration time T
ir
, function
block MPOT1
l
The set time refers to a change
of 0 ... 100 %
C0263 MPOT1 Tif
10.0
0.1
{0.1 s}
6000.0 Deceleration time T
if
, function
block MPOT1
Motor potentiometer
l
The set time refers to a change
of 100 ... 0 %
C0264 MPOT1 on/off
0
0
no change
Deactivation of motor
potentiometer, function block
MPOT1
l
Function is executed when
MPOT1−INACT = HIGH
1
Deceleration with T
if
to 0%
2
Deceleration with T
if
to C0261
3
Jump with T
if
= 0 to 0%
4
Jump with T
if
= 0 to C0261
5
Acceleration with T
ir
to C0260
C0265 MPOT1 init
0
0
Value of MPOT1 when mains fails
Initialisation of motor
potentiometer, function block
MPOT1
l
Starting value which is to be
accepted during mains
switching and activated motor
potentiometer
1
lower limit of C0261
2
0 %
C0267
s
^ Selection list 2
Configuration of digital input
signals, function block MPOT
See System
Manual
(extension)
1 CFG: UP
1000 FIXED0
UP
DOWN
MPOT1−OUT
0
0
¾
0
1
¯
1
0
1
1
¾
: Output signal runs to the upper limit
value
¯: Output signal runs to the lower limit
value
¾: Output signal is unchanged
2 CFG: DOWN
1000 FIXED0
C0268
s
CFG: INACT
1000 FIXED0
^ Selection list 2
Configuration of digital input
signal, function block MPOT
l
HIGH: motor potentiometer is
not active. Output signal runs
to 0
C0269
Digital input signals, function
block MPOT
l
Display of the signals linked in
C0267 and C0268
1 DIS: UP
2 DIS: DOWN
3 DIS: INACT