Configuration, Code table – Lenze EVF9333−xV User Manual
Page 358

Configuration
Code table
8.5
l
8.5−10
EDSVF9333V EN 4.0−11/2007
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0091
s
Mot cos phi
à
0.50
{0.01 }
1.00 Motor cos
j
à
depending on C0086
l
Motor selection in C0086 sets
the corresponding motor cos
j
in C0091
l
Change of C0091 sets
C0086 = 0
^ 6.6−1
C0092
s
Mot Ls
à
0.0
{0.1 mH}
6500.0 Motor stator inductance
à
Value is evaluated by motor
parameter identification from
C0088, C0089, C0090 and
C0091
à
Selection of a motor in C0086
sets the corresponding stator
inductance value in C0092
^ 6.6−1
C0093 DRIVE IDENT
Controller identification
l
Read only
0
invalid
Damaged power section
1
none
No power section
9321
...
9333
9321VC
...
9333VC
Display of the controller used
C0094 Password
0
0
{1}
9999 Password
l
C0094 = 1 ... 9999: Free access
to the user menu only
^ 7.2−9
C0095
s
Mot Io
à
0.00
{0.01 A}
1000.00 Motor magnetising current
à
depending on C0086, C0088
and C0091
l
Change of C0086, C0088 and
C0091 sets C0095 to the Lenze
setting
l
Change of C0095 sets
C0086 = 0
^ 6.6−1
^
6.11−5
C0096
0
no protection
No password
protection
Parameter access protection
l
Extension of the access
protection for AIF bus systems
and CAN with activated
password in C0094
l
All codes in the user menu can
continued to be accessed.
1
R protection
Read protection
2
W protection
Write protection
3
R/W protection
Read/write
protection
1 AIF protect.
0
Parameter access protection AIF
2 CAN protect.
0
Parameter access protection CAN
C0099 S/W version
x.y
Software version
l
Read only
x
y
Main version
Subversion