Configuration, Code table – Lenze EVF9333−xV User Manual
Page 376

Configuration
Code table
8.5
l
8.5−28
EDSVF9333V EN 4.0−11/2007
IMPORTANT
Possible settings
Code
Selection
Lenze
Name
No.
C0443 DIS:
DIGIN−OUT
0
{1}
255 Terminal signals, function block
DIGIN
l
Read only
l
Binary interpretation of the
terminal signals at X5
See System
Manual
(extension)
Bit
Assignment
0
DIGIN1
X5/E1
1
DIGIN2
X5/E2
2
DIGIN3
X5/E3
3
DIGIN4
X5/E4
4
DIGIN5
X5/E5
5
ST−DIGIN6
X5/ST
6
DIGIN−CINH
X5/28
C0444
0
1
LOW signal
HIGH signal
Terminal signals, function block
DIGOUT
l
Read only
See System
Manual
(extension)
DIS: DIGOUT1
Bit
Assignment
X5/A1
DIS: DIGOUT2
0
DIGIN1
X5/A2
DIS: DIGOUT3
1
DIGIN2
X5/A3
DIS: DIGOUT4
2
DIGIN3
X5/A4
C0450
s
CFG: NX
1000 FIXED0%
^ Selection list 1
Configuration of analog input
signal, function block BRK1
l
Speed threshold, from which
the drive may output the signal
"Close brake"
See System
Manual
(extension)
C0451
s
CFG: SET
1000 FIXED0
^ Selection list 2
Configuration of digital input
signal, function block BRK1
l
HIGH = close brake
l
LOW = open brake
C0452
s
CFG: SIGN
1000 FIXED0%
^ Selection list 1
Configuration of analog input
signal, function block BRK1
l
Direction of torque with which
the drive is to create a torque
against the brake
C0458
−199.99
{0.01 %}
199.99 Function block BRK1
l
Display of the signals linked in
C0450 and C0452
See System
Manual
(extension)
1
DIS: NX
2
DIS: SIGN
C0459 DIS: ON
Function block BRK1
l
Display of the signal linked in
C0451
C0464 Customer I/F
0
original
Customer interface indicates the
status of the selected basic
configuration
l
Reassignment of terminals in a
basic configuration does not
change C0005 and sets C0464
= 1
l
Adding or removing function
blocks or changing the signal
flow among the function
blocks in a basic configuration
sets C0005 = 0 and C0464= 1
1
changed