Parameter setting – Lenze EVF9333−xV User Manual
Page 251

Parameter setting
Parameter setting with the XT EMZ9371BC keypad
Changing and saving parameters
7.2
7.2.4
l
7.2−5
EDSVF9333V EN 6.2−04/2012
Action
Key
sequence
Step
T y
T z
Quick change of digit
7.
Accept the changed parameter
Display of SHPRG or SHPRG
p T V
Confirm change to accept the parameter
Display "OK"
Display
p −
The parameter has been accepted
immediately
8.
Enable the controller, if
required
U
1)
The drive runs again
9.
Change to the code level
A
V
Display of the operating level
B
V
Display of the code with changed
parameter
10. Change further parameters
Restart the "loop" with step 1. or 3.
11. Save changed parameters
A
z y Z Y
Select the code C0003 "PAR SAVE" in the
menu "Load/Store"
B
V
Change to the parameter level
Display "0" and "READY"
Select the parameter set
in which the parameters
are to be saved
permanently
C
z
Save as parameter set 1:
ð Set "1" "Save PS1"
Save as parameter set 2:
ð Set "2" "Save PS2"
Save as parameter set 3:
ð Set "3" "Save PS3"
Save as parameter set 4:
ð Set "4" "Save PS4"
D
T V
When "OK" is displayed, the settings are
permanently saved in the selected
parameter set.
12. Change to the code level
A
V
Display of the operating level
B
V
Display of C0003 "PAR SAVE"
13. Set parameters for another
parameter set
Restart the "loop" with step 1. or 3.
1)
The function of the
S key can be programmed:
C0469 = 1: Controller inhibit
C0469 = 2: Quick stop (Lenze setting)