Installing of the standard device – Lenze EVF9333−xV User Manual
Page 61

Installing of the standard device
Standard devices in the power range 15 ... 30 kW
Thermally separated mounting (push−through technique)
4.2
4.2.3
l
4.2−3
EDSVF9333V EN 6.2−04/2012
4.2.3
Thermally separated mounting (push−through technique)
For mounting in push−through technique, the drive controller of type
EVF93xx−EV must be used. In addition, the mounting set EJ0011 for
push−through technique is required.
h
c1
c2
c3
h
d1
d2
d3
d2
d
b
a1
a
g
b1
e1
e
L
9300vec116
Fig. 4.2−2
Dimensions for thermally separated mounting 15 ... 30 kW
9300 vector
Dimensions [mm]
Type
a
a1
b
b1
c1
c2
c3
d
d1
d2
d3 e
1)
e1
g
h
EVF9327−EV
EVF9328−EV
EVF9329−EV
279.5 250 379.5 350 19 131 243 361.5 32 100 97 250 159.5 6
9
1)
For a fieldbus module plugged onto X1, consider mounting space for connecting cables
EVF9327−EV
EVF9328−EV
EVF9329−EV
236
336
Dimensions
Mounting cutout in control
cabinet