5 system error messages, 1 general error messages, System error messages – Lenze EVF9333−xV User Manual
Page 455: General error messages, Troubleshooting and fault elimination, System error messages general error messages

Troubleshooting and fault elimination
System error messages
General error messages
9.5
9.5.1
l
9.5−1
EDSVF9333V EN 6.2−04/2012
9.5
System error messages
9.5.1
General error messages
)
Note!
In the case of a query via system bus (CAN), the fault messages
are represented as numbers (see first column of the table).
Fault message
Description
Cause
Remedy
No.
Display
−−−
−−−
No fault
−
−
0011
OC1
Overcurrent in motor cable
(I
a
> 2.25 x I
N
; Hardware
monitoring)
In the event of a short circuit
l
Search for the cause of the
short circuit.
l
Check the motor cable.
Capacitive charging current of the
motor cable is too high
Use motor cable which is shorter
or of lower capacitance
Too short acceleration or
deceleration times in proportion
to the load (C0012, C0013, C0105)
l
Increase the gain (P
component) of the Imax
controller (C0075).
l
Reduce integral−action time
(integral action component) of
the Imax controller (C0076)
The drive is connected to the
coasting machine. The coasting is
caused by a short−time pulse
inhibit, e.g. at
l
OU (overvoltage in the DC bus)
l
external or internal controller
inhibit
l
Activate flying restart circuit
l
Encoder error
l
Tracks during encoder
feedback of the motor speed
are interchanged
Check wiring of the encoder
DC−injection braking at high
speeds
l
See
^ 9.4−1
Missing mains phase
l
Check the connections and the
supply cable of the device
l
Check mains voltage
0012
OC2
Motor cable earth fault
One of the motor phases has
earth contact.
l
Search for cause of short
circuit.
l
Check motor cable.
0013
OC3
Overload during acceleration.
Too short acceleration or
deceleration times in proportion
to the load (C0012, C0013,
C0105).
l
Increase the gain (P
component) of the current
controller (C0075).
l
Reduce the reset time (integral
action component) of the I
max
controller (C0076).
l
Increase ramp times.
l
^ 9.4−2, "controller in clamp
operation (fault OC3)"
0015
OC5
I x t overload
l
Frequent and too long
acceleration with overcurrent
l
Continuous overload with
I
motor
> 1.05 x I
rx.
Check drive dimensioning.
0016
OC6
I
2
xt overload
l
Frequent and too long
acceleration processes with
motor overcurrent.
l
Permanent motor overload
with I
motor
>I
rmotor
Check drive dimensioning.