Lenze 8615E User Manual
Page 93

Name
Parameter (Facto-
is printed in bold)
Preselection:
Digital output Al
SH + PRG
freely
D i g i t a l o u t p u t A 2
assignable
D i g i t a l o u t p u t A 3
d i g i t a l o u t p u t
D i g i t a l o u t p u t A 4
Relay output Kl
for
N o f u n c t i o n
SH + PRG
Output frequency smaller than
Maximum
reached
Ready
P u l s e i n h i b i t
Fault
reached
Act. value =
-1
A c t . v a l u e = 0
P o l a r i t y f o r
Output HIGH active
SH + PRG
Cl17
Output LOW active
function
be assigned to one output, including the
relay output. you want to re-assign an output, the previous
is lost.
A
which is already assigned to an output,
only be
assigned to another terminal or the relay output, if the previously
used output has been assigned to another function.
of the freely assignable digital
5.4.1
Frequency below a certain threshold,
The
indicates via the assigned output that the output
frequency is smaller than the threshold set
C017. For example,
you c:an use the output for a holding brake and
CO17
at which output frequency the brake is to be released or engaged.
Code
Name
Parameter (Factory setting is printed in bold)
Acceptance
C O 1 7
Threshold for 2 Hz
7.5 Hz
(0.1 Hz}
100 Hz ON-LINE
function
480 Hz)
91