Initial on – Lenze 8615E User Manual
Page 56

Initial
on
settings are necessary for the drive to operate?
After mains connection the controller is ready to operate after
approx. 0.5 seconds.
The frequency
are factory-set such that a four-pole
Standard motor with 400V rated voltage and
according to the
in section 3.1
be operated without
settings.
In
of motor ratings according to section 3.2 or 3.3, page
it is necessary to increase the permanent output power
accordingly. Using the
Cl 19 and Cl 20 the output
monitoring must be set to increased power or maximum power (see
page 99). The I
CI
must also be adapted to the motor
(see page72).
The motorwill rotate if:
.
the controller is enabled:
Apply a voltage of 13 to 30V (HIGH
across terminal
28.
.
the
of rotation is set :
CW rotation:
Apply a voltage of 13 to 30V
(HIGH
across terminal 21.
CCW rotation:
Apply a voltage of 13 to 30V
(HIGH
across terminal 22.
the
is not
Apply a voltage
than OV (maximum 1 OV) across terminal
8.
Reference potential for the terminals 21, 22, 28 is terminal 39.
When operating with internal voltage supply (terminal
bridge
terminals 39 and 40. Reference potential for the
input
terminal 8 is terminal 7.
If you want to operate the controller using the LECOM
additional settings are required.