4 s-shaped ramp generator characteristic, 5 limitation of the frequency setting range, 6 oscillation damping – Lenze 8615E User Manual
Page 100: 7 load-change damping

6.4
S-shaped ramp generator characteristic
For the ramp generator of the main
you
select
different characteristics
Cl 34:
l
linear characteristic for all
accelerations
l
S-shaped characteristic for all jerk-free accelerations.
Code Name
Parameter
( F a c t o r y s e t t i n g i s p r i n t e d i n b o l d )
R a m p - g e n e r .
characteristic
characteristic
S-shaped charactertstic
(main setpoint)
Acceptance
[SH + PRG]
6.5
Limitation of the frequency setting range
If the drive must rotate in only one direction,
a reversal
may darnage material
you
the setting
range of the output frequency to one direction of rotation
C239.
Especially for configurations with closed-loop
control the drive
may reverse for a short time.
Code
Name
Parameter
( F a c t o r y s e t t i n g i s p r i n t e d i n
C 2 3 9 F r e q u e n c y
Frequency setting
range
bipolar
setting range
Frequency setting range unipolar
Acceptance
[SH + PRG]
6.6 Oscillation damping
Motors
are not adapted to the controller output power, may
oscillate in
with idle running. you increase the value
CO79, the oscillatlon is damped. With high chopper frequencies, the
motor noise may increase.
Code
Name
Parameter
( F a c t o r y s e t t i n g i s p r i n t e d i n b o l d )
Acceptance
C 0 7 9 ’ O s c i l l a t i o n 2 . 0
2 . 0
5.0 ON-LINE
d a m p i n g
* extended
set
6.7
Load-change damping
the load frequently
and if energy is repeatedly absorbed
by the DC bus of the controller (e.g. cyclic lifting and lowering of a
load), the controller is able to damp the increase of the
bus
voltage. The absorbed energy is reduced so that a brake chopper
may not be
You
set the damping
C234.
Code Name
Parameter
( F a c t o r y s e t t i n g i s p r i n t e d i n b o l d )
Acceptance
Load-Change 0.25
0 . 0 0
( 0 . 0 1 )
5.00 ON-LINE
d a m p i n g
* extended
set
98