5.2.6 Ramp generator stop
While the drive is accelerated via the ramp generator of the main
setpoint, you
hold the ramp generator using the assigned
digital input,
to wait for cet-tain
before accelerating.
With terminal control you
read
whether the
ramp generator is stopped or not.
With control via the keypad or the LECOM interfaces the ramp
generator (main setpoint) is stopped and enabled again
C131.
Code
Name
Parameter
( F a c t o r y s e t t i n g i s p r i n t e d i n b o l d )
Acceptance
Ramp gener.
ramp generator
SH + PRG
stop
Stop ramp generator
5.2.7 Ramp generator input =
you want to stop the drive independently of the main
(setpoint
frequency) you
the ramp generator
input input to zero using the assigned input. This
the drive
to brake with the set deceleration time. When the
is
deactivated, the main
is enabled again and the drive
accelerates normally.
With terminal control
serves as display whether the ramp
generator input is set to zero or not.
With control via keypad or LECOM interfaces you
set the ramp
generator to zero and enable it again
Cl 32.
Code
Name
Parameter (Factory setting is printed in bold)
Acceptance
Cl32
R a m p g e n e r a t o r i n p u t e n a b l e d
SH PRG
generator input
Ramp generator input =
0
set to zero
5.2.8 Integral action component =
In configurations with Pl controller you
set the integral action
component of the controller to zero using the assigned input. See
page 80.