5 additional acceleration and deceleration times – Lenze 8615E User Manual
Page 88

5.2.5 Additional acceleration and deceleration times
For the ramp generator of the main
(setpoint
frequency) you
additonal acceleration and deceleration
times from the memory, e.g. to
the acceleration
of
the drive as from a certain
Programming of additional acceleration and deceleration
times
The ramp times are set in two
one pair of
acceleration and deceleration times is selected.
l
Select an additional
time
Cl 00
l
Set the desired acceleration time
and the desired
deceleration time
Cl 03.
you need several additional ramp times, repeat the two
correspondingly.
To calculate the values to be entered, please observe the information
on page 74.
A maximum of 15 additional acceleration and deceleration times
be programmed.
C o d e ( N a m e
Parameter (Factory
setting is printed in
Acceptanct
Cl 00 Preselection:
Pair of ramp times 1
+ PRG
A d d i t i o n a l
Pair of
times 2
a c c e l e r a t i o n
. .
. .
d e c e l e r a t i o n
P a i r o f r a m p t i m e s 1 5
t i m e
A c c e l e r a t i o n
2.5 s
0.00 s
1
s ON-LINE
time for Cl 00
1 . 0 s
(100 ms)
10.0s
1 0 s
100s
100s
990 s
Cl 03 Deceleration 2.5 s
t i m e f o r
0.00 s
1
s ON-LINE
1 . 0 s
(100 ms)
10.0s
100s
100s
990 s
Assignment of the digital inputs
The number of required inputs for the function “Enable additional
acceleration/deceleration times” depends on the amount of the
required additional ramp times.
Number of required acceleration and deceleration
times
Number of required Inputs
at least
at least
2
at least 3
4
A maximum of four inptus
be assigned to this function. For the
assignment of the inputs see the
on page 81.
86