2technical data, 1 general data – Lenze 8615E User Manual
Page 13

2
Technical data
2.1
General data
M a i n s v o l t a g e :
O u t p u t v o l t a g e :
Output frequency:
Chopper frequency:
Threshold of the integrated brake
Enclosure:
A m b i e n t t e m p e r a t u r e :
Noise
Permissible
3 x
AC, 45 to 65 Hz
Permissible voltage range:
V
(as alternative:
DC
3
X
0
fd with 400V at
adjustable, mains-independent)
When using a mains
the maximum possible output voltage is
reduced to approx. 96% of the mains voltage.
0 to
adjustable
to
4kHz factory
adjustable from 2 to
765 V DC in the DC bus
housing,
to DIN 40050
0 t o 5 0 ° C
O p e r a t i o n
(for rating see page 19)
-25 to 55°C
storage
-25 to 70°C
transport
Severity
4 to IEC 801-4
P o l l u t i o n
l
2 to VDE 0110,
2. The
should not be exposed to
or explosive
I n f l u e n c e o f
a l t i t u d e o n
1 0 0 0 m : 1 0 0 % r a t e d
the rated
2000 m: 95% rated
3000 m: 90% rated
4000 m: 65% rated
11