Automation status word (58c4 – Lenze 2130IB User Manual
Page 84

L
82
5.4.2.
Automation status word (58C4
hex
)
Data format:
Unsigned16
The parameter "automation status word" is used to show compact
information about the drive system. It contains status information of the
controller states and other important information.
Structure of the parameter "automation status word":
Bit
Name
Meaning
0
Ready to switch on
Controller status information
0 = state at least"READY TO SWITCH ON"
1 = state less than "READY TO SWITCH ON"
1
Switched on
Controller status information
0 = state at least "SWITCHED ON"
1 = state less than "SWITCHED ON"
2
Operation enabled
Controller status information
0 = state at least "OPERATION ENABLED"
1 = state less than "OPERATION ENABLED"
3
Malfunction
Controller status information
0 = no malfunction (TRIP)
1 = malfunction (TRIP)
4
Voltage disabled
Information about command "disable voltage"
(see "control word").
0 = command is active
1 = command is not active
5
Quick stop
Information about command "quick stop" (see "control word").
0 = command is active
1 = command is not active
6
Switch on disabled
Controller status information
0 = State not "SWITCH ON DISABLED"
1 = State "SWITCH ON DISABLED"
7
Warning
Collective warning; not supported at the moment.
0 = no warning
1 = warning
8
Message
Collective message; not supported at the moment.
0 = no warning
1 = warning
9
Remote
Bus access authority; depending on the Lenze parameter
"operating mode" (L-C001)
0 = L-C001 <> 5
1 = L-C001 = 5
10
OM-Stat10
2211: not used
2212: not used
Automation status function 10 depends on the automation
software package.
0 = inactive
1 = active
11
OM-Stat11
2211: not used
2212: not used
Automation status function 11 depends on the automation
software package.
0 = inactive
1 = active
12
OM-Stat12
2211: not used
2212: not used
Automation status function 12 depends on the automation
software package.
0 = inactive
1 = active
13
OM-Stat13
2211: not used
2212: not used
Automation status function 13 depends on the automation
software package.
0 = inactive
1 = active