4.4. Malfunction / Monitoring
4.4.1.
Malfunction code (603F
hex
)
Data format:
Unsigned16
The malfunction code has an equivalent profile code, if the controller has
recognized a fault (TRIP). The Lenze parameter L-C067 (index 5FBC
hex
)
contains corresponding Lenze error information, possibly with more
detailed information. The Lenze parameters L-C161 - 168 (index 5F5E
hex
- 5F57
hex
) contain the base controller fault history.
The following DRIVECOM malfunction codes can currently be generated:
Lenze
fault
indication
DRIVECOM malfunction code
hex dez
Meaning
OC
2300
8960
General overcurrent
OC1
2320
8992
Short circuit, overload
OC2
2330
9008
Earth fault
OC3
2213
8723
Overcurrent during acceleration
OC4
2214
8724
Overcurrent during decleration
OC5
2311
8977
I
∗t monitoring
OC6
2312
8978
I
2
t monitoring
OC7
2311
8977
I
2
∗t monitoring
OU1
3211
12817
Overvoltage during deceleration
OUE
3212
12818
Overvoltage fault
LU1
3130
12592
Phase missing
LP1
3130
12592
Phase failure
LP3
3100
12544
Mains failure
FE
3140
12608
Mains frequency fault
LF
3142
12610
Mains frequency too low
OF
3141
12609
Mains frequency too high
OH
4210
16656
Overheat heatsink
OH1
4410
17424
Overheat supply module
OH2
4210
16912
Overheat axis module
OH3
4310
17168
Overheat motor
CE0
8100
33024
Automation interface time monitoring
U15
5111
20753
Vcc15 supply defective
CCr
6010
24592
System failure
Pr
6310
25360
Parameter reset
PEr
6100
24832
Program error
OL
2300
8960
Overload of outputs
SP
7302
29442
Incorrect polarity of feedback source
Sd1
7301
29441
Analog signal source defective
Sd2
7303
29443
Resolver wire breakage
Sd3
7305
29445
Incremental encoder defective
EEr
9000
36864
External trip
UEr
1000
4096
Unknown fault
dEr
7120
28960
Motor malfunction
ACI
3321
13089
Armature circuit interrupted
Hxx
5000
20480
Self test error
150
8000
32768
General process fault
151
8612
34322
Limit switch negative
152
8612
34322
Limit switch positive
153
8611
34321
Following error 1
154
8611
34321
Following error 2