Aif process data base controller – Lenze 2130IB User Manual
Page 80
L
78
5.3. AIF process data base controller
At the moment, the following Lenze parameters can be mapped to the
PROFIBUS process channel:
Function
Data
type
PCD
4900 series
(L-C, index)
8600 series
(L-C, index)
9200 series
CP-n
set
I16
POI
±16384 = ±100%
Reference: n
max
(380;5E83)
±16384 = ±100%
Reference: n
max
(380;5E83)
±26884 = ±100%
Reference: 8000
rpm
(380;5E83)
CP-n
set2
I16
PI
±16384 = ±100%
Reference: n
max
(381;5E82)
±16384 = ±100%
Reference: n
max
(381;5E82)
±26884 = ±100%
Reference: 8000
rpm
(381;5E82)
CP-n
actual
I16
PI
16384 = ±100%
Reference: n
max
(382;5E81)
±16384 = ±100%
Reference: n
max
(382;5E81)
±26884 = ±100%
Reference: 8000
rpm
(382;5E81)
CP-M
set
116
PI
16384 = ±100%
Reference: M
max
Function L-C056
(388;5E7B)
---
±32767 = ±100%
Function: L-C056
(387;5E7C)
CP-M
limit
116
PO
16384 = ±100%
Reference: M
max
Function L-C047
(388;5E7C)
---
±32767 = ±100%
Function: L-C047
(388;5E7B)
CP-actual
angle
U16
PI
0 .. 65535
360° = 16384
(391;5E78)
---
0 .. 65535
360° = 16384
391;5E78)
CP-field
current set-
value
I16
POI
16384 = ±100%
Reference: L-C083
(392;5E77)
---
---
CP-additional
set-value
I16
PI
16384 = ±100%
Function L-C049
(393;5E76)
---
---
CP-FDI1
OS2
POI
Bit 0 ... 7
Terminal E1 ... E8
(136,5F77)
Bit 0 ... 7
Terminal E1 ... E8
(136,5F77)
---
CP-FDO1
OS2
PI
Bit 0 ... 4
Terminal A1 ... A5
(151,5F68)
Bit 0 ... 4
Terminal A1 ... A5
(151,5F68)
---
For explanations about the columns "Data type" and PCD" see chapter
"code table DRIVECOM" (page 52).
Further information can be obtained from the operating instructions of the
base controllers.