General commands – Festo Контроллер двигателя CMMD-AS User Manual
Page 36
3. Product description
36
Festo P.BE-CMMD-AS-HW-EN 1002NH
After reset, the serial interface always has the following basic settings:
Parameter
Value
Baud rate
9600 Baud
Data bits
8
Parity
None
Stop bits
1
Table 3.5 Default parameter
To be able to operate an interface with a terminal program, such as for test purposes, the
following settings are required (recommendations):
Parameter
Value
Flow control
None
Emulation
VT100
ASCII configuration
- Sent characters finish with line feed
- Output entered characters locally (local echo)
- During reception, attach line feed to the end of the line
Table 3.6 Setting for terminal program
Please note that, immediately after a reset, the motor controller independently issues a
bootup message via the serial interface. A reception program on the controller must either
process or reject these received characters.
General commands
Command
Syntax
Response
New initialisation of the servo positioning controller
RESET!
None (bootup message)
Save the current parameter set and all position sets in the
non-volatile flash memory.
SAVE!
DONE
Setting the baud rate for serial communication
BAUD9600
BAUD19200
BAUD38400
BAUD57600
BAUD115200
Unknown command
as desired
ERROR!
Read the version number of the CM (Configuration
Management) release of the firmware
VERSION?
2300:VERSION:MMMM.SSSS*)
*)MMMM:
Main version of the CM release (hexadecimal format)
SSSS:
Subversion of the CM release (hexadecimal format)
Table 3.7 General commands